Kaikki kirjat 25 % alennuksella koodilla: BOOKS

  • check Yli 10 miljoonaa kirjaa
  • check Uutuuksia joka päivä
  • check Yli 1 miljoona asiakasta luottaa meihin
  • check Hyvät hinnat ja alennukset
  • check Toimitus koko Eurooppaan

Patch-Clamp Applications and Protocols -

englanti
2013-08-23
127,04 € 169,38 €

-25% koodilla BOOKS

Toimittajalla varastossa

Toimitus 12-18 arkipäivässä

30 päivän palautusoikeus

E. Neher and B. Sakman were the first to monitor the opening and closing of single ion channels and membranes by conductance measurements. In 1976, they used firepolished micropipets with a tip diameter of 3-5 pm to record currents from a small patch of the membranbe of sk- etal muscles, thereby decreasing background membrane noise. In order to reduce the dominant source of background noise-the leakage shun ... Täydellinen kuvaus

Saatat myös pitää

Kuvaus

E. Neher and B. Sakman were the first to monitor the opening and closing of single ion channels and membranes by conductance measurements. In 1976, they used firepolished micropipets with a tip diameter of 3-5 pm to record currents from a small patch of the membranbe of sk- etal muscles, thereby decreasing background membrane noise. In order to reduce the dominant source of background noise-the leakage shunt under the pipet rim between m- the muscle membrane had to be treated brane and gla- enzymatically. Despite these early limitations, a new te- nique was born -the patch-clamp technique. The final bre- through came in 1981 when the same authors, in collaboration with 0. P. Hamill, A. Marty, and F. J. Sigworth, developed the gigaohm seal. Not only did this improve the quality of recordings, it was now possible to gently pull the membrane patch with the attached pipet off the cell and study its trapped ion channels in isolation. Another offshoot of the gigaohm seal technique was the whole-cell patch-clamp technique, in which the patch is ruptured without breaking the seal. This technique is really a sophisticated voltage-clamp technique and also allows for the altering of cytoplasmic constituents if the experimenter so wishes. The first part of Patch-Clamp Applications and Protocols presents modern developments associated with the techn- ogy of patch-clamp electrodes, of cell-free ion channel reco- ing, and of the whole-cell patch-clamp technique.

Lisätietoja

Julkaisija Humana Press
Series Neuromethods
Julkaisuvuosi 2013
Kannen tyyppi Pehmeäkantinen
EAN 9781489940643
Kirjoita oma arvostelusi
Arvostelet: Patch-Clamp Applications and Protocols
Arvostelusi:

Goodreads-arvostelut

127,04 € 169,38 €